COMBUSTIBLE DUST: NFPA® 652 IS FINALLY HERE... HOW WILL IT AFFECT FLAME-RESISTANT CLOTHING?

NFPA® 652 is the standard published in 2015 regarding combustible dust (CD). While previous CD standards, including NFPA® 654, were inconsistent and industry-specific, NFPA® 652 is the first to provide a consistent and complete set of safety requirements across all industries whose processes cause a CD hazard. This whitepaper addresses the implications of the new standard for safety managers and will help explain how the new provisions may affect your business operations and FR safety programs.

Fill Out the Form Below to Download Our Free Whitepaper.

Stay Informed

The best way for you and your team to reduce injury in the case of a combustible dust event is to stay educated. The Bulwark Protection PPE experts provide a wide range of tools and resources on how to select the right PPE clothing and tips on how to properly implement a safety program.

  • Whitepaper – Combustible Dust
  • NFPA® 652
  • NFPA® 2112

  • NFPA® 2113

Stay Informed

The Bulwark Protection PPE experts help you and your team to stay up to date on the sea of standards, regulations and hazards your industry faces including:

  • NFPA® 70E

  • Visibility
  • Arc Flash

  • Combustible Dust

Good to Go From Head to Toe

Depending on your line of work, there are a number of hazards you may encounter on the job. Bulwark Protection offers PPE that protects against:

  • Arc Flash
  • Flash Fire
  • Chemical Splash
  • Combustible Dust
  • Molten Metals
  • Visibility
PROTECTION THAT KEEPS UP WITH DEMAND
We know that your team works in hazardous environments, and they need to be protected against all of the various risks they may face—whether that’s arc flash, combustible dust or another hazard. That’s why Bulwark Protection offers PPE clothing that will provide comfort and safety for general industry electricians and manufacturing facilities workers.
Free Home Wash Magnet

Our free FR Home Wash magnet is packed with FR laundering quick tips. Request your free magnet to learn more, and keep it handy wherever you launder your garments.

Fill Out the Form Below to Request Your Magnet

Ask An Expert
What is a Hazard Risk Assessment?

AR, FR, ATPV, OSHA. The list goes on and on. If there’s one thing that’s true about FR safety, it’s that there are a lot of terms to memorize. It’s not always easy to keep the various words and acronyms straight, but when it comes to building and implementing an effective safety program, knowing your FR vocabulary is important. Here, our FR experts have compiled the most important of those terms in a handy alphabetized glossary so you can create a culture of compliance.

Arc Flash
An arc flash is a type of electrical explosion where temperatures can reach or exceed 35,000 °F. The Arc Flash hazard affects all who work in and around energized electrical equipment. This can include general industry electricians, maintenance workers and operators, as well as our electric utilities, including transmission, distribution, generation and metering.

Arc-Rated (AR) Protective Clothing
Arc-rated protective clothing protects from arc flash and electric arc hazards. AR garments are measured in cal/cm². The total AR clothing system must meet or exceed required arc protection levels. Remember, all AR is FR, but not all FR is AR.

Breakopen
Breakopen is the formation of holes in the fabric during arc rating testing. This is the point of failure of FR protective garments.

EBT
Energy Break-Open Threshold is an alternative measure to ATPV when that measure cannot be used due to breakopen.

Flash Fire
A rapid moving flame front that can be caused by a diffuse fuel, such as dust, gas, or the vapors of an ignitable liquid, without the production of damaging pressure. Flash fire is the primary hazard in the Oil & Gas industry, which includes exploration, drilling, field services and refining.

Hazard Risk Assessment
The first step in the creation of any PPE program is the Hazard Assessment. Federal regulations require employers to assess the workplace to determine if hazards that require the use of personal protective equipment are present or are likely to be present. These include impacts, combustible dust, fire/heat, and chemical hazards, among others.

HRC (Hazard Risk Category)
Hazard risk categories are defined by NFPA® 70E and assigned based on risk associated with electrical safety and arc flash. HRC levels determine the appropriate ATPV of flame-resistant clothing for a given task.

PPE Category
Replaces HRC in 2015 edition of NFPA 70E, the “0” category was eliminated in NFPA 70E 2015. The minimum ATPV’s for PPE Category 1 through 4 are the same as they were for HRC, and the new PPE table only specifies PPE for work within the arc flash boundary.

CAT 2
HRC 2 rated garments have an arc rating between 8 cal/cm² and 25 cal/cm² and are often referred to as “daily wear.”

CAT 3
HRC 3 rated garments have an arc rating between 25 cal/cm² and 40 cal/cm².

CAT 4
HRC 4 rated garments have an arc rating equal or greater than 40 cal/cm². These high ratings are achieved with a layered FR system. Download our FR Layering Fact Sheet to learn the do’s and don’ts of layering for FR.

Inherently Flame Resistant
Inherently flame resistant fabrics are engineered to be flame-resistant at the fiber level, and do not require any additional finishing.

NFPA®
The National Fire Protection Association is an agency whose task it is to promote and improve fire protection and prevention. They publish National Fire Codes.

NFPA® 2112
Refers to NFPA’s “Standard on Flame Resistant Garments for Protection of Industrial Personnel Against Flash Fire.” NFPA® 2112 is the “go-to” industry consensus standard that addresses flash fire. It defines the testing methods and performance requirements for flame-resistant fabrics for this hazard.

NFPA® 70E
The “Standard for Electrical Safety in the Workplace,” NFPA® 70E is meant to protect those working around potential arc flash hazards. Note that NFPA® 70E applies only to general industry electrical safety, not to electric utility workers.

OSHA

Founded by the Occupational Safety & Health Act of 1970, The Occupational Safety and Health Administration’s (OSHA) mission is to “assure safe and healthful working conditions for working men and women by setting and enforcing standards and by providing training, outreach, education and assistance.” Their general duty clause ensures a safe workplace for all employees and is the basis for all industry consensus standards. OSHA determines regulations and standards related to personal protective equipment.

OSHA 1910.269

The regulation states that power utilities make reasonable estimates of the incident heat energy to which their employee would be exposed, and that employees exposed to hazards from electric arcs wear AR clothing and other protective equipment with an arc rating greater than or equal to the estimated heat energy.

ANSI

Founded in 1918, The American National Standards Institute coordinates and develops voluntary standards for products, services, and systems. The organization’s goals include performance consistency and product safety. It is the U.S. member body to ISO and IEC.

PPE (Personal Protective Equipment)

Personal protective equipment is specialized safety gear worn by an employee for protection against a hazard. Flame resistant/arc rated garments are a form of personal protective clothing worn against thermal hazards.

Moisture Wicking

Moisture wicking fabrics pull moisture (sweat) away from the body and dry quickly, keeping the wearer cooler, dryer, and more comfortable. Bulwark iQ Series® FR Comfort Knits and Wovens are among the best moisture wicking FR garments available.

Breathability

Breathability refers to how well a fabric allows air to be transmitted through the material. The more air that passes through, the cooler the wearer stays. Bulwark iQ Series® Endurance Collection is the first of its kind to offer high level FR protection in a material that is extremely breathable and durable.

Safety Updates
The ABC’s of PPE

Building a PPE program that meets all safety requirements and meets your personal needs is no easy task. You must select the right garments based on the unique hazards of your industry, in addition to important factors like comfort, durability and laundering. But even the best PPE program in the world is ineffective without the proper implementation and training. Below, we’ll provide you with a step-by-step process for designing, implementing and maintaining your PPE program.

Hazard Assessment
The first step in the creation of any PPE program is the Hazard Assessment. Federal regulations require employers to assess the workplace to determine if hazards that require the use of personal protective equipment are present or are likely to be present. Using the Hazard Assessment Checklist, you will conduct a walk-through survey of the workplace to identify potential hazards. These include impacts, combustible dust, fire/heat, and chemical hazards, among others. When conducting your assessment, be sure to consider workplace, procedural, and environmental hazards.

Selecting the Right PPE
Once you’ve established the need for PPE, it’s time to determine the degree of protection required based on your particular hazards. We do this by matching the hazard to the regulations, which inform what, if any, PPE is required. Industry consensus standards may be used to guide selection decisions, and the best way to cite these standards is by industry. For the main industries Bulwark serves, the hazards and standards are as follows:

Oil & Gas, which includes exploration, drilling, field services, refinement, and chemical, faces the known hazard of flash fire, a rapidly moving flame front that expands through diffuse fuel without creating blast pressure.

NFPA® 2112 and NFPA® 2113 are the “go-to” industry consensus standards that address flash fire. NFPA® 2113 focuses on how organizations and employers—as well as individual wearers—should choose the correct garment based on certain criteria.

Electric Utility workers, including those working in the transmission, distribution, generation, and metering of power utilities, are exposed to hazards associated with electrical energy, primarily electrical arcs or arc flashes.

General Industry: Wherever workers may be exposed to hazards associated with electrical energy, employers must make sure they are protected. This includes electricians, maintenance workers, and operators.

NFPA 70E® requires AR (or arc-rated) clothing for any potential exposure above 1.2 cal/cm2, which equals the onset of a second-degree burn. The level of protection must be based on the task at hand, and most general industry tasks will require CAT2 or higher. It’s necessary to carefully consider the actual risk associated with a job and to match the protection category accordingly.
NOTE: NFPA 70E® applies only to general industry electrical safety. To address specific circumstances for utility, OSHA published 1910.269 & 1926.960, which state that power utilities are required to wear arc-rated clothing which matches the potential threat as determined by a proper hazard analysis.

Training
Employers implementing a PPE program are required by OSHA 1910.132(f)(1) and all industry consensus standards to provide training to each employee. According to OSHA, each employee who is required to wear PPE should at least know when it is necessary, what exactly is necessary, the do’s and don’ts of proper wear, what its limitations are, and how to properly care for it.

NFPA® 2112 A.5.1.1 offers specific requirements about the information employers must provide to their employees.

Maintenance
Proper care and maintenance of FR/AR clothing is essential to the effectiveness of your PPE program. While most industry standards recommend following the instructions provided by compliant garment manufacturers, some standards offer specific guidance, and there are a few basic rules that apply across all relevant standards.

1. Do not use any kind of bleach or peroxide

2. Do not use any additive that could build up and impede FR performance

3. Wash FR/AR garments separately

4. Turn FR/AR garments inside out to help color retention and preserve appearance

5. Use liquid detergent for best results

6. Avoid the hottest temperature to reduce the impact of shrinkage

7. For tough stains, apply liquid detergent or stain remover and soak garment

8. For even tougher stains, Bulwark® FR garments can be dry cleaned

9. Tumble dry on low setting and do not over dry

10. Rewash garments with lingering odor

11. Never use DEET or any other flammable substances on FR/AR clothing.

12. Any repairs must be made with fabric and findings that match the protection level of the original garment.

 

More specific regulations about PPE maintenance are defined in NFPA® 2113 and NFPA 70E®.